Leak test unit PFA 0/6-600
The leak test unit PFA 0/6-600 has been designed for testing tap fittings up to nominal diameter 600. The test medium is air. The system consists of 2 twin test stands; a third twin test stand is prepared. With regard to its test programs, the system has been designed to test the housing as well as the valve seat at a test pressure of 3 bar. The test specimens are inserted and removed manually, the test procedure runs automatically.
The test parameters input is realised in a customer-specific manner from permanently programmed values via manually changeable ones up to the type-specific test database. The test results are also evaluated customer-specifically, from simple signalling of the test result via signing to a database of the test results with automatic certificate generation.
Technical data
Testable range: tap fittings up to nominal diameter 600
Test method: medium air; evaluation by pressure drop
Test duration: adjustable; ca. 1 min.
Utilities connections:
Test method: medium air; evaluation by pressure drop
Test duration: adjustable; ca. 1 min.
Utilities connections:
- Elt: 230V/10A/50Hz
- Compressed air: 7-10 bar